Interlock XT ST-182-2005
Images (4) Videos (0)
360° (1) Interactive (0)

Product benefits

First blow, then turns on the ignition
Prior to starting the engine, the Dräger Interlock XT requests a breath sample. If the driver has alcohol in their breath above the preset limit , the immobiliser system inhibits the motor from starting. Otherwise, the starter is activated for the driver to start the vehicle. The device can also prompt the driver to retest periodically while en route. The device will not disrupt the engine function once the engine has been started, however the event will be recorded. Some countries require the horn to sound and / or the headlamps to flash if a retest is failed.
High measurement accuracy
The Dräger Interlock XT determines the breath alcohol concentration via an electro-chemical sensor system as it is used in respective police measuring devices. The device is responsive to alcohol only.
Fast usability
To avoid long waiting periods, Dräger put emphasis on the Interlock XT always being fast ready to use quickly. Its functionality is as good at -40 °C as at +85 °C under direct sunlight. The name affix "XT" stands for "eXtended Temperature".
Safe from manipulation
The device immediately detects any attempt to use auxiliaries as air pumps or filters to bypass the Dräger Interlock XT. In such case, it will inhibit the motor from starting.
All events recorded in a data memory
The data memory records more than 30.000 events and can be read via a special PC software.

Product Information

Accessories

Interlock Mouthpiece

Mouthpieces

  • Mouthpieces in packs of 5, 50 and 300, with or without non-return valve
Interlock Mouthpiece Tip

Mouthpiece cap

  • Easily exchangeable cap for frequent driver change.
Interlock Connection Cable

Curly cord

  • Curly Cord to connect the hand and the control unit, with lengths of 1.5 m and 6m.
Interlock cradle

Holder

  • Holder to mount the handset in the driver's compartment.

Related Products

alcotest_9510_st-421-2006.jpg
Dräger Alcotest 9510

The Alcotest® 9510 is a state of the art dual sensor breath alcohol measurement instrument. With ease of use, modern design, touch screen graphic display and several communication connections to peripheral devices, the Alcotest® 9510 sets new standards for evidential breath testing.

Dräger Alcotest 7110 Evidential
Alcotest 7110 Mk V Evidential

The Dräger Alcotest 7110 Evidential is the only breathalyzer which is type-approved in Germany as an evidential device. It meets the most stringent requirements for breathalyzers worldwide, as they were laid down in DIN VDE 0405.

Alcotest 7510
Dräger Alcotest 7510

Whether for the police or the commercial sector: The Dräger Alcotest® 7510 allows for breath alcohol analysis for any application, and is listed on the National Highway Traffic Safety Administration's Conforming Product List (NHTSA CPL) as an evidential breath tester. This instrument will most likely be the first handheld breath tester compliant with OIML 126R.

alcotest-6810-.jpg
Dräger Alcotest 6810

Alcotest® 6810 provides a quick and accurate breath alcohol analysis for professional users. This instrument has UK Home Office Type Approval and is listed on the National Highway Traffic Safety Administration Conforming Products List (NHTSA CPL) as an Evidential Breath Tester for Department of Transportation applications.

Dräger Alcotest 6510
Dräger Alcotest® 6510

The Alcotest® 6510 offers professional users rapid and precise breath-alcohol analysis in a compact, user-friendly form. This instrument is Type approved by the UK Home Office for roadside screening and listed on the National Highway Traffic Safety Administration Conforming Products List (NHTSA CPL) as an Evidential Breath Tester for Department of Transportation applications.

drugtest_st-13214-2007
Dräger DrugTest 5000

No pipetting, no dripping, no timing: Not only sampling is done quickly and easily with the Dräger DrugTest® 5000. Directly afterwards, the sample also can be evaluated automatically – for reliable results on the spot.

SSK5000_D-6296-2009.jpg
Dräger SSK 5000

The Draeger SSK 5000 is used for sampling for drugs on or from surfaces. When used in combination with the Dräger DrugTest® 5000, the sample is transferred to a test cassette and screened for possible drug contamination from that surface. For further testing, the collected sample can be stored and transported.

dcd_5000_st-13227-2007.jpg
Dräger DCD 5000

Reliable preservation of evidence: Via the Dräger DCD5000, approximately 0.4 ml of oral fluid sample can be sampled, preserved and transported. The sampler shows a minimum volume variance. Thanks to reproducible recovery rates, semi quantitative conclusions can be drawn, concerning the concentration of the substance classes to be analyzed which were present in the sample at the moment of sampling.

Literature

Certificates

Test Certificate: EN 50436-1

Alcohol interlocks - Test methods and performance requirements Part 1: Instruments for drink-driving-offender programs.

Test Certificate: EN 50436-2

Alcohol interlocks - Test methods and performance requirements - Part 2: Instruments having a mouthpiece and measuring breath alcohol for general preventive use.